Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-111-2520 Item Description: Resistor Variable N | 5905 | 011112520 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
91-84-0 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.188 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.375 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.190 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 215.0 MAXIMUM |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.190 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 2.000 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
91.00.08.2A2001 | 91-0001 | 91-000-471-00 | 91-0001 |
91-000035 | 91-000-471-00 | 91.00.08.2A2001 | 91-00002 |
91-000-471-00 | 91-0000 | 91-000-471-00 | 91-000-1 |
91-0001-12 | 91.00.08.2A2001 | 91-0001 | 91-000038 |