5905-00-755-2212 Item Description: Resistor Variable W | 5905 | 007552212 | 0 | N | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9112591 | 3 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 1.375 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 11.500 INCHES NOMINAL |
ABKW | III OVERALL HEIGHT | 0.300 INCHES MINIMUM AND 0.320 INCHES MAXIMUM |
ABMK | III OVERALL WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.300 INCHES MINIMUM AND 0.320 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 175.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD |
ABTB | MOUNTING HOLE DIAMETER | 0.086 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.100 INCHES MINIMUM AND 0.120 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.060 INCHES MINIMUM AND 0.080 INCHES MAXIMUM |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.000 KILOHMS SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
911-00221-005 | 911-0201-0067 | 911-0201-0073 | 911-0040 |
911-02 | 911 0201 0065 | 911-0 | 911-0201-0049 |
911.004.4 | 911-0201-0067 | 911 001 | 911-0201-0049 |
911-0201-0066 | 911-0 | 911-002-0001 | 911-0040-176-2044 |