Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-254-2364 Item Description: Resistor Variable N | 5905 | 002542364 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
203828 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR BUSHING MOUNTED |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.260 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.374 INCHES MAXIMUM |
ABKW | III OVERALL HEIGHT | 0.759 INCHES MAXIMUM |
ABMK | III OVERALL WIDTH | 0.300 INCHES MAXIMUM |
ABWV | SHAFT DIAMETER | 0.110 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.015 INCHES MAXIMUM |
ADAP | MOUNTING BUSHING LENGTH | 0.085 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.260 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.300 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.385 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEDZ | SHAFT BEARING TYPE | SLEEVE |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
AXGY | MOUNTING METHOD | SNAP-IN AND TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.000 OHMS SINGLE SECTION |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 260.0 NOMINAL |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
203-0002-019 | 203-00032-001 | 203-000-536-1 | 203-0001 |
203-00-6905-1 | 203-0004-002 | 203-0001-01 | 203-000-001 |
203-000007-999 | 203-000-001 | 203 00 084 | 203-0001 |
203-0002-019 | 203-0004-050 | 203 00 085 | 203-000-001 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.