Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-380-7283 Item Description: Circuit Breaker | 5925 | 013807283 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7274-62-1 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ADAQ | BODY LENGTH | 0.750 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
ABXD | BUSHING LENGTH | 0.359 INCHES NOMINAL |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND SAND RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF |
AKPX | POLE QUANTITY | 1 |
THSD | THREAD SERIES DESIGNATOR | UNS |
PKWT | III UNPACKAGED UNIT WEIGHT | 29.0 GRAMS |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CMLP | THREAD QUANTITY PER INCH | 32 |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.593 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.562 INCHES NOMINAL |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 800.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.287 INCHES MINIMUM AND 1.317 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
727-00-00 | 727-0020-4 | 727-0020-4 | 727-0020-4 |
727-001-218 | 727-01-00509 | 727-0012-002 | 727-01-00509 |
727-0020-4 | 727-001-259 | 727-0001 | 727-001-259 |
727-01-00509 | 727-0028-004 | 727-001-218 | 727-000 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |