5925-01-118-2484 Item Description: Circuit Breaker | 5925 | 011182484 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
05390 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.546 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.750 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
AKPX | POLE QUANTITY | 1 |
ABMK | OVERALL WIDTH | 1.025 INCHES NOMINAL |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 35.0 DC SINGLE LOCATION |
ADAT | BODY WIDTH | 1.025 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.750 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | BREAKER HAS FOUR TERMINALS IN BACK TWO FOR COIL,FOR ONE LINE,ONE FOR LOAD |
SR-5 | DESIGN CONTROL REFERENCE | CD-1-Z8-1-35DCP |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 MILLIAMPERES DC SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
SR-5 | MANUFACTURERS CODE | 74193 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
AJEC | BOSS HEIGHT | 0.218 INCHES NOMINAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 3.547 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | USED ON SHIPS SERVICE SWITCH ON BAORD 140' WTGB C.G. VESSELS |
ABHP | OVERALL LENGTH | 3.764 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SINGLE LOCATION |
SR-5 | THE MANUFACTURERS DATA | |
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 35.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERVOLTAGE SINGLE LOCATION |
ADTV | CASE MATERIAL | PLASTIC |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
053-002-198 | 053-000689 | 053-0021-0001 | 053-00012-PM |
053-00089 | 053-002-198 | 053-0020-0001 | 053-00012-P1 |
053-0021 | 053-0021-0001 | 053-000689 | 053-00089 |
053-0021 | 053 00091 | 053-0021-0003 | 053-00089 |