Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-937-2137 Item Description: Switch Toggle | 5930 | 009372137 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1100076 | 3 | 1 | C | 9 |
MRC | Criteria | Characteristic |
---|---|---|
TOGGLE | AAJD | THREAD CLASS2A |
TOGGLE | AAQL | BODY STYLEBUSHING MOUNT |
TOGGLE | ABHP | OVERALL LENGTH0 562 INCHES MAXIMUM |
TOGGLE | ABKW | OVERALL HEIGHT1 359 INCHES NOMINAL |
TOGGLE | ABMK | OVERALL WIDTH0 408 INCHES MAXIMUM |
TOGGLE | ABXD | BUSHING LENGTH0 170 INCHES NOMINAL |
TOGGLE | ADAQ | BODY LENGTH0 562 INCHES MAXIMUM |
TOGGLE | ADAT | BODY WIDTH0 354 INCHES MAXIMUM |
TOGGLE | AFUQ | ACTUATOR STYLEROUND |
TOGGLE | AFUS | ACTUATOR HEIGHT0 440 INCHES NOMINAL |
TOGGLE | AFUX | ACTUATOR POSITION-ACTION RELATIONSHIPUP POSITION MAINTAINED AND DOWN POSITION MAINTAINED AND CENTER POSITION MAINTAINED |
TOGGLE | AFVA | ACTUATOR COLORBLACK SINGLE ACTUATOR |
TOGGLE | AFXE | MAXIMUM VOLTAGE RATING IN VOLTS115 0 AC AND 28 0 DC |
TOGGLE | AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE0 749 INCHES MAXIMUM |
TOGGLE | AKNA | INCLOSURE TYPEFULLY INCLOSED |
TOGGLE | AXGY | MOUNTING METHODTHREADED BUSHING |
TOGGLE | CMLP | THREAD QUANTITY PER INCH40 |
TOGGLE | CQJX | NOMINAL THREAD SIZE0 250 INCHES |
TOGGLE | CRLD | NONPILE-UP CONTACT ARRANGEMENT1 POLE DOUBLE THROW THREE POSITIONS MAINTAINED SINGLE SWITCH UNIT |
TOGGLE | CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5 000 AMPERES RESISTIVE DC AND 1 000 AMPERES INDUCTIVE DC AND 3 000 AMPERES RESISTIVE AC AND 2 000 AMPERES INDUCTIVE AC |
TOGGLE | FEAT | SPECIAL FEATURESBLACK OXIDE FINISH ON ACTUATORBUSHINGAND FACENUT |
TOGGLE | PMLC | PRECIOUS MATERIAL AND LOCATIONTERMINAL SURFACES GOLD |
TOGGLE | THSD | THREAD SERIES DESIGNATORUNS |
TOGGLE | TTQY | TERMINAL TYPE AND QUANTITY3 TAB SOLDER LUG |
110-00-008 | 110-0000-037 | 110-000-192 | 110-00 |
110-00000 | 110-000-002 | 110-0000-037 | 110.000.190 |
110.000.436 | 110.000.219 | 110.000.438 | 110.000.178 |
110-00-00-00-00 | 110.000.444 | 110-00-008 | 110.000.137 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote