Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5920-00-901-4731 Item Description: Fuseholder Extracto | 5920 | 009014731 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Fhl10u | 1 | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
EXTRACTOR POST | AAFZ | BODY MATERIALPLASTIC DIALLYL PHTHALATE MIL-M-14 TYPE SDG |
EXTRACTOR POST | AAQL | BODY STYLEPANEL MOUNTED TYPE |
EXTRACTOR POST | ABDM | TERMINAL MATERIALANY ACCEPTABLE |
EXTRACTOR POST | ABDN | TERMINAL SURFACE TREATMENTANY ACCEPTABLE |
EXTRACTOR POST | ABHP | OVERALL LENGTH3 750 INCHES MINIMUM AND 4 000 INCHES MAXIMUM |
EXTRACTOR POST | ABKW | OVERALL HEIGHT1 812 INCHES MINIMUM AND 1 817 INCHES MAXIMUM |
EXTRACTOR POST | ABMK | OVERALL WIDTH1 180 INCHES MINIMUM AND 1 185 INCHES MAXIMUM |
EXTRACTOR POST | ABTB | MOUNTING HOLE DIAMETER0 151 INCHES MINIMUM AND 0 161 INCHES MAXIMUM |
EXTRACTOR POST | ABTJ | MOUNTING HOLE QUANTITY2 |
EXTRACTOR POST | ADZC | ENVIRONMENTAL PROTECTIONSALT SPRAY PROOF |
EXTRACTOR POST | AEVB | MOUNTING HOLE STYLE2 BUSHING MOUNTING W2 HOLES |
EXTRACTOR POST | AFRG | CONTACT MATERIALANY ACCEPTABLE |
EXTRACTOR POST | AFRH | CONTACT SURFACE TREATMENTSILVER PLATED QQ-S-365 |
EXTRACTOR POST | AFXH | INTERRUPTION INDICATOR METHODNEON LAMP |
EXTRACTOR POST | AGUE | FUSE ACCOMMODATION QUANTITY2 |
EXTRACTOR POST | AGUJ | ACCOMMODATED FUSE LENGTH1 250 INCHES NOMINAL |
EXTRACTOR POST | AGUK | ACCOMMODATED FERRULE DIAMETER0 250 INCHES NOMINAL |
EXTRACTOR POST | AGUN | RESISTOR RATING120 0 KILOHMS |
EXTRACTOR POST | AGUP | INDICATING LAMP VOLTAGE RANGE IN VOLTS90 0250 0 |
EXTRACTOR POST | AGUT | LENGTH FROM FRONT PROTRUSION TO MOUNTING SURFACE0 798 INCHES MINIMUM AND 0 828 INCHES MAXIMUM |
EXTRACTOR POST | AGVB | CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG WIDTH0 933 INCHES MINIMUM AND 0 943 INCHES MAXIMUM |
EXTRACTOR POST | AGVF | BUSHING HOLE DIAMETER0 869 INCHES MINIMUM AND 0 879 INCHES MAXIMUM |
EXTRACTOR POST | AGVK | CENTER TO CENTER DISTANCE BETWEEN BUSHING HOLES0 795 INCHES MINIMUM AND 0 805 INCHES MAXIMUM |
EXTRACTOR POST | AGVM | CENTER TO CENTER DISTANCE BETWEEN KEYWAY AND BUSHING HOLE0 464 INCHES MINIMUM AND 0 474 INCHES MAXIMUM |
EXTRACTOR POST | AJYN | SCREW THREAD DIAMETER0 164 INCHES NOMINAL |
EXTRACTOR POST | AJYQ | SCREW THREAD QUANTITY PER INCH32 0 |
EXTRACTOR POST | CQJL | CURRENT CARRYING RATING IN AMPS30 0 |
EXTRACTOR POST | CSNM | FUSE TERMINAL TYPE ACCOMMODATEDFERRULE |
EXTRACTOR POST | ELEC | VOLTAGE IN VOLTS250 0 |
EXTRACTOR POST | PMLC | PRECIOUS MATERIAL AND LOCATIONCONTACTS SILVER |
EXTRACTOR POST | PRMT | PRECIOUS MATERIALSILVER |
EXTRACTOR POST | TEST | TEST DATA DOCUMENT81349-MIL-F-19207 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTI |
EXTRACTOR POST | TTQY | TERMINAL TYPE AND QUANTITY4 THREADED STUD |
EXTRACTOR POST | ZZZK | SPECIFICATIONSTANDARD DATA81349-MIL-F-192071 GOVERNMENT SPECIFICATION |