Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-439-5786 Item Description: Filter Band Pass | 5915 | 004395786 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
0300d0169 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
BAND PASS | ABHP | OVERALL LENGTH4 478 INCHES MINIMUM AND 4 522 INCHES MAXIMUM |
BAND PASS | ABKW | OVERALL HEIGHT1 660 INCHES MAXIMUM |
BAND PASS | ADAQ | BODY LENGTH4 478 INCHES MINIMUM AND 4 522 INCHES MAXIMUM |
BAND PASS | ADAT | BODY WIDTH2 226 INCHES MINIMUM AND 2 234 INCHES MAXIMUM |
BAND PASS | ADAU | BODY HEIGHT1 100 INCHES MAXIMUM |
BAND PASS | AEBV | UNTHREADED MOUNTING HOLE DIAMETER0 161 INCHES NOMINAL |
BAND PASS | AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4 125 INCHES NOMINAL |
BAND PASS | AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1 875 INCHES NOMINAL |
BAND PASS | AFGA | OPERATING TEMP RANGE-40 0 TO 175 0 DEG FAHRENHEIT |
BAND PASS | AHAJ | REFERENCE FREQUENCY PER FUNCTION61 0 MEGAHERTZ BLANK |
BAND PASS | AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION50 0 OHMS BLANK |
BAND PASS | AHAS | LOAD IMPEDANCE PER FUNCTION50 0 OHMS BLANK |
BAND PASS | AHCH | AVERAGE POWER RATING PER FUNCTION1 0 WATTS BLANK |
BAND PASS | AKNA | INCLOSURE TYPEENCAPSULATED |
BAND PASS | AXHR | MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE |
BAND PASS | CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS10 0 BLANK |
BAND PASS | CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR RECEPTACLE INPUT 1ST FUNCTION |
BAND PASS | CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION54 00 MEGAHERTZ BLANK AND 59 00 MEGAHERTZ BLANK AND 63 00 MEGAHERTZ BLANK AND 68 00 MEGAHERTZ BLANK |
BAND PASS | CQRG | BODY MATERIALMETAL |
BAND PASS | CRBB | FREQUENCY BAND WIDTH PER FUNCTION59 00 MEGAHERTZ BLANK AND 63 00 MEGAHERTZ BLANK |
BAND PASS | CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS54 0 MINIMUM BLANK AND 12 0 MINIMUM BLANK AND 12 0 MINIMUM BLANK AND 62 0 MINIMUM BLANK |
BAND PASS | FEAT | SPECIAL FEATURESBOTH TERMINALS ON ONE SURFACE |
BAND PASS | STYL | STYLE DESIGNATORRECTANGULAR TERMINALTERMINALS ON TWO SURFACES |
BAND PASS | TEST | TEST DATA DOCUMENT19200-10549196 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote