Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-155-4730 Item Description: Transformer Power | 5950 | 001554730 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
38z243 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.115 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.240 INCHES MINIMUM AND 3.260 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.427 INCHES MINIMUM AND 3.447 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.052 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 0.104 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 0.156 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 0.208 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 0.259 AC |
CWJS | WINDING OPERATING VOLTAGE | 0.467 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 3.63 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 4.15 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 4.67 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 5.19 AC VOL |
CWJS | WINDING OPERATING VOLTAGE | 7.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 21 TURRET |
38Z160 | 38Z160 | 38Z157 | 38Z248 |
38Z239 | 38Z239 | 38Z248 | 38Z1 |
38Z160 | 38Z157 | 38Z239 | 38Z225 |
38Z157 | 38Z208 | 38Z18 | 38Z208 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote