MRC | Criteria | Characteristic |
---|---|---|
AACT | CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
AWZJ | POWER SOURCE | EXTERNAL |
APMM | DIAL SCALE MARKING COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
AMQY | INSTALLATION DESIGN | PANEL |
ZZZV | III FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |
NHCF | NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
AQFY | BACKGROUND COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
SFTT | SURFACE TREATMENT | ENAMEL |
APPN | ACCURACY IN PERCENT | -2.0 TO 2.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
BLSB | SCALE SELECTION METHOD | TERMINAL |
ASSS | POINTER COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
AKYN | FURNISHED ITEMS AND QUANTITY | MTG HDW 3 |
BHMW | MEASUREMENT RANGE | 0.0 TO 60.0 VOLTS, DC SINGLE INDICATOR SINGLE RANGE |
AMKD | INDICATOR TYPE | DIAL W/POINTER |
FEAT | SPECIAL FEATURES | RUGGEDIZED |
ABHP | OVERALL LENGTH | 2.307 INCHES MINIMUM AND 2.319 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 3.494 INCHES MINIMUM AND 3.506 INCHES MAXIMUM |
BHDC | SCALE GRADUATION TYPE | LINEAR SINGLE INDICATOR SINGLE RANGE |
ANRL | MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
BHSX | (NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
APST | METER DEPTH BEHIND MOUNTING FLANGE | 1.244 INCHES MINIMUM AND 1.256 INCHES MAXIMUM |
CBBL | FEATURES PROVIDED | ZERO ADJUSTER |
ANTG | SENSITIVITY RATING | 50.0 MILLIVOLTS |
MATT | MATERIAL | STEEL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
APSN | (NON-CORE DATA) PANEL FOR WHICH DESIGNED | MAGNETIC OR NONMAGNETIC |
AFFL | MOUNTING BOLT CIRCLE DIAMETER | 3.063 INCHES MINIMUM AND 3.188 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.156 INCHES NOMINAL |
CTTD | CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 THREADED STUD |
ADZC | ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
MARK | SPECIAL MARKINGS | BAND FROM 0 TO 42 V MARKED LEAD ACID 18 CELL; RED LINE AT 42 V |
ABWG | SCALE DIVISION QUANTITY | 60 SINGLE INDICATOR SINGLE RANGE |
STYL | STYLE DESIGNATOR | C1 ROUND FLUSH MTG |
APSW | METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.744 INCHES MINIMUM AND 2.756 INCHES MAXIMUM |
SPCL | SPECIAL TEST FEATURES | CONFORMS TO MIL-M-10304 |