Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ASSB | MECHANICAL CONNECTION QUANTITY | 3 |
AXGY | MOUNTING METHOD | PANEL |
ASSC | MECHANICAL CONNECTION SIZE | 1/8 IN. DIA |
ELEC | VOLTAGE IN VOLTS | 12.0 OR 24.0 |
APSJ | SCALE QUANTITY | 1 AND 1 AND 1 |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | AN5733-1A |
ASSH | INSTRUMENT LAMP | NOT INCLUDED |
ABMK | OVERALL WIDTH | 3.250 INCHES NOMINAL |
ACDC | CURRENT TYPE | DC |
AQFZ | SCALE NAME | OIL PRESSURE AND OIL PRESSURE AND FUEL PRESSURE |
BBHK | SCALE RANGE | 0 TO 30 PSI AND 0 TO 200 PSI AND MINUS 50 DEG C TO PLUS 150 DEG C |
BBHL | SCALE SMALLEST INCREMENT GRADUATION | 1 PSI AND 10 PSI AND 10 DEG |
BBJN | TEMP INDICATOR DEVICE | ELECTRICAL |
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
AKSF | CONTACT TYPE | PIN |
ABHP | OVERALL LENGTH | 2.938 INCHES MINIMUM AND 3.125 INCHES MAXIMUM |
ASKZ | ELECTRICAL CONNECTION IDENTIFYING NUMBER | PART NO. AND1006-14S-2P |
ASKY | ELECTRICAL CONNECTION CONTROLLING AGENCY | AN |
SR-1 | MANUFACTURERS CODE | 88044 |
SR-1 | SPEC/STD CONTROLLING DATA | |
ASKX | ELECTRICAL CONNECTION QUANTITY | 1 |
ASSD | MECHANICAL CONNECTION TYPE | INTERNAL PIPE |
AFRA | CONTACT QUANTITY | 4 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |