Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-323-7552 Item Description: Transformer Power | 5950 | 003237552 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6514650 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.375 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.812 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 65.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 120.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 113.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 12.40 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 12.40 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 12.80 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY12.80 AC VOL |
CWJS | WINDING OPERATING VOLTAGE | 12.40 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 12.40 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY12.80 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY12.80 AC VOLTS M |
CWJS | WINDING OPERATING VOLTAGE | 12.40 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 6.20 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 113.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 12.80 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY6.40 AC VOLTS |
CWJS | WINDING OPERATING VOLTAGE | 6.20 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 113.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 419.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 6.40 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY532.00 AC VOL |
CWJS | WINDING OPERATING VOLTAGE | 6.20 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 6.40 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 13 PIN |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote