Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-615-5010 Item Description: Attenuator Fixed | 5985 | 016155010 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
18dh-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAFS | APPLICATION DESIGN | TRANSMISSION LINE |
AAQL | BODY STYLE | ROUND, TERMINAL/TERMINALS IN OPPOSITE SURFACE |
AHTY | INPUT IMPEDANCE RATING IN OHMS | 50 |
AJDB | POWER RATING | 2.0 WATTS AVERAGE |
AXGY | MOUNTING METHOD | CONNECTOR |
BNGR | FREQUENCY RANGE | 2.5 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM |
AFGA | OPERATING TEMP RANGE | -65.0 TO 125.0 DEG CELSIUS |
ABHP | OVERALL LENGTH | 0.700 INCHES NOMINAL |
AAFZ | BODY MATERIAL | STEEL, STAINLESS |
ABEM | BODY SURFACE TREATMENT | PASSIVATED |
ADAV | OVERALL DIAMETER | 0.313 INCHES NOMINAL |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.15 AND 1.20 AND 1.25 AND 1.35 |
AHTZ | OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | SMA |
AJDK | RF SIGNAL ATTENUATION IN DECIBELS | 2.0 |
ASZN | CONNECTION TYPE PER FUNCTION | FEMALE OUTPUT AND MALE INPUT |
BBHS | TERMINAL TYPE AND QUANTITY | 2 CONNECTOR |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | DH ATTENUATORS |
18D05430C02 | 18D-12 | 18D 14 | 18D-5 |
18D-DIP | 18D0366 | 18D05 | 18D-3 |
18D05310C01 | 18D04 | 18D-12 | 18D-14 |
18D00 | 18D-12 | 18D05 | 18D00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote