Note : We Will Not Share Your Information To Any Third Parties.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-032-1848 Item Description: Filter Radio Freque | 5915 | 010321848 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
73a0000-000 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 4.382 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.870 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.4 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.4 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.4 3RD RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 02660 |
AHBP | INPUT TERMINAL IDENTIFICATION | 348-40E14-019P1 |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 CONNECTOR |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
TEST | TEST DATA DOCUMENT | 21101-73A0000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
73A-0238 | 73A-0222 | 73A-0226 | 73A-0097 |
73A-0213 | 73A-0227 | 73A-0220 | 73A-0228 |
73A-0215 | 73A-0234 | 73A-021 | 73A-0222 |
73A-0221 | 73A-0239 | 73A-0223 | 73A-0236 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote