Note : We Will Not Share Your Information To Any Third Parties.
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 6.062 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.312 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.250 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+55.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | +0.0/+52.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 1.5 SINGLE RADIO INTERFERENCE PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 600.0 SINGLE HIGH PASS TWO PHASE TO TWO PHASE |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 20.0 KILOHMS 1ST BAND PASS |
AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | 20.0 KILOHMS 2ND BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 2.0 KILOHMS 1ST BAND PASS |
AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 2.0 KILOHMS 2ND BAND PASS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.0 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.0 2ND BAND PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 100.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 500.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 700.00 HERTZ 2ND BAND PASS 2ND FUNCTION AND 1.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 600.00 HERTZ 1ST BAND PASS 1ST FUNCTION AND 1.10 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 1.90 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 2.40 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.10 KILOHERTZ 1ST BAND PASS AND 1.90 KILOHERTZ 1ST BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 500.00 HERTZ 2ND BAND PASS AND 700.00 HERTZ 2ND BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 1.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 1.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 40.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 1.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 1.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 40.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote