5970-00-855-6250 Item Description: Insulation Sleeving | 5970 | 008556250 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
307a8858p1 | 2 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS |
AFZU | MAIN BODY INSIDE DIAMETER | 0.730 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU | MAIN BODY INSIDE DIAMETER | 1.520 INCHES MINIMUM AS SUPPLIED |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
AFZZ | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH | 2.830 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 2.570 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | 0.120 INCHES MAXIMUM AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAC | FIRST BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAD | SECOND BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
AGAD | SECOND BRANCH WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
AGAF | FOURTH BRANCH WALL THICKNESS | 0.070 INCHES MAXIMUM AS SUPPLIED |
AGAF | FOURTH BRANCH WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 2.950 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
HUES | COLOR | BLACK |
MATT | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.760 INCHES MINIMUM AS SUPPLIED |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
FLEX | FLEXIBILITY | SEMIRIGID |
STYL | STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
307 0006 040 | 307-0000 | 307-0018-00 | 307-0009-00 |
307-0002-010 | 307-0018-00 | 307-0007-00 | 307-0009-00 |
307-0002-010 | 307-0004 | 307-00 | 307-0015-00 |
307-0007-00 | 307-0018-00 | 307 0025 00 | 307-0006-00 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote