Part No | Part Type | Description | QTY | RFQ |
---|---|---|---|---|
FN9260-1-06 | filters | mod pwr entry inlet w/fuse 1a 1a fuse holder general purpose included panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN2450G-10-61 | filters | filter 1-phase emc 10a power line 250v 10a 4.9mh chassis mount terminal block | Avl | RFQ |
FN9233ES1-15-06 | filters | filter hi perform w/choke 15a 15a - general purpose fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
RS514-0 5-02 | filters | choke differential 48uh .5a horz power line 2 48¦h 500ma 800 mohm - through hole 0.886"" l x 0.846"" w (22.50mm x 21.50mm) 0.520"" (13.20mm) horizontal 4 pc pin -40¦c ~ 125¦c tray | Avl | RFQ |
FN3359-800-99 | filters | filter 3-phase hi current 800a power line 300v 520v 800a - chassis mount quick connect | Avl | RFQ |
FN9233U-1-06 | filters | filter hi perform iec inlet 1a 1a - general purpose fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN9263S-2-06 | filters | mod pwr ent snap-in w/switch 2a 2a switch on/off non-illuminated general purpose fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN3270H-10-29 | filters | filter compact 3-ph emc/rfi 10a power line 300v 520v 10a - chassis mount terminal block | Avl | RFQ |
FN9676-16-03 | filters | filter 1-phase compact emi 16a power line 250v 16a 10.2mh chassis mount terminal block | Avl | RFQ |
RN152-8-02 | filters | choke compensated 2.7mh 8a horz power line 2 2.7mh 8a 22 mohm - through hole 1.693"" l x 1.646"" w (43.00mm x 41.80mm) 0.996"" (25.30mm) horizontal 4 pc pin -40¦c ~ 125¦c tray | Avl | RFQ |
FN9263S-10-06 | filters | mod pwr ent snap-in w/switch 10a 10a switch on/off non-illuminated general purpose fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN9233-8-06 | filters | filter hi perform iec inlet 8a 8a - general purpose fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN350-55-33 | filters | filter 1-phase 55a for drives power line 250v 55a - chassis mount terminal block | Avl | RFQ |
FN7563-32-M4 | filters | cap feedthrough ac 32a y4 0.47¦f 130v 32a 0.63 mohm -40¦c ~ 100¦c axial - threaded terminals tray - 1.260"" dia x 3.228"" l (32.00mm x 82.00mm) m20 x 1 | Avl | RFQ |
FN405-3-02 | filters | filter compact 3a pcb power line 250v 3a 2mh through hole pcb pins | Avl | RFQ |
FN9222R-10-06 | filters | filter performance iec inlet 10a 10a - general purpose fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN9233ESB-15-06 | filters | filter hi perform med choke 15a 15a - medical fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN3400-16 5-33 | filters | filter 3-phase reactor 16.5a power line 277v 480v 16.5a - chassis mount terminal block | Avl | RFQ |
FN9263-4-06 | filters | mod pwr entry inlet w/switch 4a 4a switch on/off non-illuminated general purpose fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
RN114-1-02 | filters | choke compensated 15mh 1a horz power line 2 15mh 1a 375 mohm - through hole 0.886"" l x 0.846"" w (22.50mm x 21.50mm) 0.531"" (13.50mm) horizontal 4 pc pin -40¦c ~ 125¦c tray | Avl | RFQ |
FN9246-3-06 | filters | filter hi perform iec inlet 3a power line 250v 3a 14mh chassis mount quick connect | Avl | RFQ |
FN420-2 5-13 | filters | filter 1-phase general emi 2.5a power line 250v 2.5a 3.4mh chassis mount quick connect | Avl | RFQ |
FN2070M-12-06 | filters | filter multi-stage perform 12a power line 250v 12a 3.25mh chassis mount quick connect | Avl | RFQ |
FN7660-75-M6 | filters | filter feedthrough ac 75a y4 power line 650v 75a - chassis mount stud lug | Avl | RFQ |
FN9233E-6-06 | filters | filter hi perform w/choke 6a 6a - general purpose fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN286B-4-06 | filters | mod pwr inlet compact filter 4a 4a fuse holder switch on/off non-illuminated medical included panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
RN202-1 5-02 | filters | choke compensated 1.6mh vert power line 2 1.6mh 1.5a 100 mohm - through hole 0.717"" l x 0.346"" w (18.20mm x 8.80mm) 0.543"" (13.80mm) vertical 4 pc pin -40¦c ~ 125¦c tray | Avl | RFQ |
FN351-280-37 | filters | filter 3-phase general emc 280a power line 250v 440v 280a - chassis mount terminal block | Avl | RFQ |
FN286B-1-06 | filters | mod pwr inlet compact filter 1a 1a fuse holder switch on/off non-illuminated medical included panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN3258-42-47 | filters | filter ultra-compact 3-phase 42a power line 277v 480v 42a - chassis mount terminal block | Avl | RFQ |
EH35-2 0-02-20M | filters | choke rfi supp 20mh 2a horiz power line 2 20mh 2a 150 mohm - through hole 1.417"" l x 1.417"" w (36.00mm x 36.00mm) 1.130"" (28.70mm) horizontal 4 pc pin -25¦c ~ 100¦c tube | Avl | RFQ |
FN351H-16-29 | filters | filter 3-phase emc hi power 16a power line 300v 520v 16a - chassis mount terminal block | Avl | RFQ |
FN5010-10-99 | filters | filter output pwn 10a power line 230v 400v 10a 4.2mh chassis mount terminal block | Avl | RFQ |
RN232-2 5-02 | filters | choke compensate 5.6mh 2.5a vert power line 2 5.6mh 2.5a - - through hole - - vertical 4 pc pin -40¦c ~ 125¦c tray | Avl | RFQ |
FN7562-16-M4 | filters | cap feedthrough ac 16a y4 0.1¦f 130v 16a 0.62 mohm -40¦c ~ 100¦c axial - threaded terminals tray - 0.787"" dia x 2.953"" l (20.00mm x 75.00mm) m12 x 1 | Avl | RFQ |
FN355-20-03 | filters | filter compact 3ph neutral 20a power line 250v 440v 20a - chassis mount terminal block | Avl | RFQ |
FN2080A-10-06 | filters | filter multi-stage hi perf 10a power line 250v 10a 4.5mh chassis mount quick connect | Avl | RFQ |
FN9222ES1B-3-06 | filters | filter snap-in w/choke med 3a 3a - medical fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
RB8522-50-0M8 | inductors coils chokes | pcb choke vert .75mh 50a 750¦h 50a - - toroidal -30% +50% unshielded 1.7 mohm - - emi filter - 2.362"" l x 1.988"" w x 3.150"" h (60.0mm x 50.5mm x 80.0mm) through hole box | Avl | RFQ |
FN2070-25-08 | filters | filter multi-stage perform 25a power line 250v 25a 2mh chassis mount stud lug | Avl | RFQ |
FN2320Y-10-06 | filters | filter 1-phase perform emi 10a power line 250v 10a 1.3mh chassis mount quick connect | Avl | RFQ |
FN388-2-21 | filters | mod pwr entry inlet filtered 2a 2a fuse holder switch on/off non-illuminated general purpose included panel mount screw hole solder iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN3256H-64-34 | filters | filter 3-phase neutral line 64a power line 300v 520v 64a - chassis mount terminal block | Avl | RFQ |
FN2080B-3-06 | filters | filter multi-stage hi perform 3a medical 250v 3a 9.8mh chassis mount quick connect | Avl | RFQ |
FN9222ESB-3-06 | filters | filter snap-in w/choke med 3a 3a - medical fuse not required panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN9222EB-10-06 | filters | filter perform med w/choke 10a 10a - medical fuse not required panel mount screw hole quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN285-10-06 | filters | mod pwr inlet compact filter 10a 10a fuse holder switch on/off non-illuminated general purpose included panel mount snap-in quick connect iec 320-c14 (male pins) 250vac | Avl | RFQ |
FN2020-16-08 | filters | filter 1-phase general emi 16a power line 250v 16a 650¦h chassis mount stud lug | Avl | RFQ |
FN2450G-16-61 | filters | filter 1-phase emc 16a power line 250v 16a 1.84mh chassis mount terminal block | Avl | RFQ |
FN2070-1-06 | filters | filter multi-stage perform 1a power line 250v 1a 22mh chassis mount quick connect | Avl | RFQ |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.